Model G-WS

Model G-WS


Specifications
Details

Optimal for low-cost treatment of water-soluble gas, space-saving, wet-type exhaust abatement system
  • Wet-type exhaust abatement system
  • Multiple gas batch processing
  • Countermeasures against by-products
  • Long-term maintenance interval
  • Low running costs
  • Low initial costs
  • Possible to deal with CE marking/SEMI-S2/NRTL

Features and Benefits

Is a wet-type exhaust abatement system that can be installed and operated with a low cost. It requires no fuel and a long-term maintenance cycle is realized based on Ebara's unique countermeasures against by-products that have been cultivated in combustion-type exhaust abatement systems for more than ten years. High uptime contributes to stable operation and reduction of maintenance costs and labor.
In addition, the maintenance space is in the front of the device only. A flexible layout is possible even for limited sub-fab space.
Gas to be treated: Water-soluble gas, such as NH3, DCS, TiCl4, WF6, HF, and HCl, which can be treated at room temperature

Specifications

 
Model   Units G-WS1000
Maximum treated air volume   L/min 1,000
Number of connected inflow entrances     4
External dimensions   mm W 914 x D 736 x H 1,727
     
Power use Water quantity L/min 1 - 10
Displacement L/min 1 - 10
Nitrogen L/min 15-50
Power supply   1.8-3.5 kW, three-phase AC 200 V (50/60 Hz)
Exhaust duct (treated gas) m3/min 1.5
Exhaust duct (housing exhaust) m3/min 1.3
Main processable gases Epi   HCl, DCS
CVD   WF6, NH3, TiCl4, BCl3, ClF3, SiF4, Cl2*, F2*
Etching   BCl3, HCl, HF, HBr, SiF4, Br2*, Cl2*, F2*
Asher   NH3
Gases that cannot be treated by wet-type     H2, SiH4, PH3, GeH4, CH4, PFCs (CF4, SF6, NF3) etc.
* Please contact Ebara when treating